Possible to use EtherCAT and Parallel I/O boards at the same time on the RC8A controller?

Modified on Wed, 24 Jan 2024 at 03:40 PM

Yes, you can use both an EtherCAT board and a Parallel IO expansion board at the same time on RC8, RC8A, and RC8A Safe Motion robot controllers.


You can use the following in conjunction with a Parallel I/O board, as the Fieldbus cards are controlling System I/O, and the Parallel card is simply providing additional discrete I/O.


After installing the desired cards, select the appropriate setup in the WinCAPS project and you will see the I/O allocation desired.




Related Links



Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article